To assess the safety of penstock in a small power station where some segments of penstock are defective with incomplete longitudinal weld, we built the finite element model of the penstock segment which contains such defects using ANSYS Workbench to solve the circumferential stress of penstock wall, and to determine the critical stress intensity factor of 16Mn steel. Furthermore, we built the finite element meshes of fractures in accordance with the weld’s defect characteristics and calculated the type I stress intensity factor at the tip of defect. Finally, according to the criterion of critical stress intensity factor, we concluded that the weld defects had no impact on the penstock safety, and did not expand in subsequent inspections.

Key words

penstock / safety evaluation / weld defect / ANSYS / finite element / stress intensity factor

Cite this article

Download Citations
LI Dong-ming, DU Wei-qiong, WU Xin-fang. Safety Assessment of Penstock in Power Station Based on Stress Intensity Factor Using ANSYS[J]. Journal of Changjiang River Scientific Research Institute. 2021, 38(5): 55-60 https://doi.org/10.11988/ckyyb.20200204

References

[1] 白 杨.带有环向内裂纹的薄壁钢管结构断裂力学计算分析[J].兰州理工大学学报,2014,40(10):169-172.
[2] 王亚新,谢禹钧.基于GB/T 19624—2004对含缺陷压力管道的安全评定[J].石油化工高等学校学报,2007,20(2):54-57.
[3] 范天佑.断裂理论基础[M].北京:科学出版社,2003:74.
[4] 胡长廉.压力容器安全可靠性及应用实例[M].北京:北京科学技术出版社,1993:81.
[5] 张洪才,何 波.有限元分析:ANSYS13.0从入门到实战[M].北京:机械工业出版社,2011.
[6] CVDA—1984,压力容器缺陷评定规范[S].北京:化工出版社,1985.
[7] 王晓芳,翁 荻,金志江,等.含未焊透缺陷工业管道的强度分析与安全评定[J].轻工机械,2010,28(2):94-98.
[8] 朱小刚. 高水头电站压力钢管安全评定[D].成都:西南交通大学,2009:11-14.
[9] SL281—2003,水电站压力钢管设计规范[S].北京:中国水利水电出版社,2003.
[10] 孟昭北.含未焊透缺陷复杂压力管道的安全性综合分析评定方法[J].压力容器与管道,2014(7):38-39.