Journal of Changjiang River Scientific Research Institute ›› 2023, Vol. 40 ›› Issue (4): 134-140.DOI: 10.11988/ckyyb.20211097

• HYDRAULIC STRUCTURE AND MATERIAL • Previous Articles     Next Articles

Characteristics and Modelling of Adiabatic Temperature Rise Rate of Medium-volumed Fly-Ash Concrete

QUAN Juan-juan1, FU Shao-jun2, YANG Ru-dong1, CHEN Jian1, ZHANG Kai-feng3   

  1. 1. Shaanxi Key Laboratory of Safety and Durability of Concrete Structure, Xijing University, Xi'an 710123, China;
    2. School of Civil Engineering, Wuhan University, Wuhan 430072, China;
    3. China West Construction North Co., Ltd., Xi'an 710065,China
  • Received:2021-10-21 Revised:2022-01-03 Online:

Abstract: Adiabatic temperature rise rate is the key factor affecting the adiabatic temperature rise of concrete. Indoor adiabatic temperature rise test was carried out on fly-ash (content 35%) concrete. The test was controlled with three initial temperatures and five water-binder ratios. The influence rules of initial temperature and water-binder ratio on the adiabatic temperature rise and the rise rate were examined. The standard of dividing three stages of adiabatic temperature rise rate was put forward. A three-stage model of adiabatic temperature rise rate of medium-volumed fly ash concrete was established. The model takes into consideration water-binder ratio, initial temperature and age, and predictes accurately the adiabatic temperature rise rate at each age.The results can provide reference for temperature adiabatic controlling of mass concrete.

Key words: adiabatic temperature rise, rate of adiabatic temperature rise, fly-ash concrete, initial temperature, water-binder ratio, three-stage model

CLC Number: