Journal of Changjiang River Scientific Research Institute ›› 2018, Vol. 35 ›› Issue (12): 64-67.DOI: 10.11988/ckyyb.20170534

• ENGINEERING SAFETY AND DISASTERP REVENTION • Previous Articles     Next Articles

Causes of Damage of the Trash Rack of a Hydropower Station with Roof Overflow

GUO Hong-hao1, ZHANG Xiao-feng2   

  1. 1.Hanjiang-to-Weihe River Valley Diversion Project Construction Co., Ltd., Xi’an 710100, China;
    2. Taoqupo Reservoir Irrigation Management Bureau, Tongchuan 727000, China
  • Received:2017-05-11 Published:2018-12-01 Online:2018-12-01

Abstract: The trash rack at the inlet of generating unit of a powerhouse with roof overflow is destroyed off the gate slot suffering from a 20-year event flood. To find out the causes of damage, we simulated the longitudinal flow pattern in the water diversion canal, and analyzed the forces on trash rack according to simulation result. Results suggest that strong transverse vortex and negative pressure in the fore-bay were induced by roof overflow. Affected by long-time longitudinal flow impact and flow pulsation, the trash rack gradually lost strength and experienced deformation, and was ultimately destroyed off the gate slot. We suggest that the impact of longitudinal flow should be considered in the design of trash rack of the same type power station to avoid similar accidents.

Key words: overflow of powerhouse roof, bulb turbine generating unit, trash rack, transverse vortex, flow pulsation

CLC Number: