JOURNAL OF YANGTZE RIVER SCIENTIFIC RESEARCH INSTI ›› 2010, Vol. 27 ›› Issue (6): 54-57.
• HEALTHY CHANGJIANG RIVER • Previous Articles Next Articles
HOU Yan-ling, SHI Yu-chuan, LI Da-xin
Online:
Published:
Abstract: With a stack body of some hydroelectric power station left bank as an example,in order to obtain rubble anti-hear intensity parameters, the results of the direct shear test and triaxial compression test were compared and analyzed. Experimental results show that: the rubble anti-hear intensity parameters measured by the triaxial compression test are more true and accurate and the applicable conditions of the two test results are also expounded; fast-hear test is fit for a high-peed plastic clay which has a smaller permeability coefficient and is to be loaded fast, but it is not fit for the soil which possesses anisotropy and unknown shear-reaking surface,in addition, in comparison with triaxial compression test,the results of fast-hear test are quite different for coarse-rained soil which possesses stronger permeability; the non-onsolidated and undrained shear test is suit for general clay and sand soil, except soil disturbed easily, and the test results are closer to the real.
Key words: rubble, large sized shear test, triaxial compression test, anti-hear intensity
CLC Number:
TV411.7
HOU Yan-ling, SHI Yu-chuan, LI Da-xin . Strength Parameters for Stack Body of Some Hydroelectric Power Station Left Bank[J]. JOURNAL OF YANGTZE RIVER SCIENTIFIC RESEARCH INSTI, 2010, 27(6): 54-57.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: http://ckyyb.crsri.cn/EN/
http://ckyyb.crsri.cn/EN/Y2010/V27/I6/54