JOURNAL OF YANGTZE RIVER SCIENTIFIC RESEARCH INSTI ›› 2013, Vol. 30 ›› Issue (10): 127-130.

• INFORMATION TECHNOLOGY APPLICATION • Previous Articles    

Analysis on the Energy-Saving Efficiency of Flow Control by Frequency Conversion Regulating for the Water Supply System of River Model Experiment

HU Xiang-yang1, XU Ming1, ZHANG Wen-er1, MA Zhi-min2   

  1. 1.River Department, Yangtze River Scientific Research Institute, Wuhan 430010, China;
    2.School of Electronic Information, Wuhan University, Wuhan 430072, China)
  • Received:2013-10-16 Revised:2013-10-16 Online:2013-10-15 Published:2013-10-16

Abstract: The energy consumptions of flow control by regulating valve and by frequency conversion in river model experiment’s water supply system are analyzed in details. Results show that the energy efficiency is lower and the wear of equipment is heavier by traditional regulating valve. On the contrary, by frequency conversion, the rotational speed of pump is directly controlled according to the flow, which saves the energy consumption of the water supply process to the maximum with the average energy saving efficiency up to 69%. The benefit of frequency conversion regulating is remarkable in the water supply system of river model experiment with high energy consumption. It’s of great value to be applied and popularized.

Key words: river model experiment, frequency conversion control of pump, flow regulating, energy saving