JOURNAL OF YANGTZE RIVER SCIENTIFIC RESEARCH INSTI ›› 2015, Vol. 32 ›› Issue (2): 119-122.DOI: 10.3969/j.issn.1001-5485.2015.02.024

Previous Articles     Next Articles

Dynamic Prediction of Concrete Temperature for the Plugging of Bottom Diversion Outlet of Xiangjiaba Hydropower Project

ZHOU Jian-bing1,HUANG Yao-ying2,HE Xiao-peng1,TIAN Kai-ping2   

  1. 1.Xiangjiaba Project Construction Department, Three Gorges Corporation, Yibin 644600, China;
    2.College of Hydraulic and Environmental Engineering, Three Gorges University, Yichang 443002, China
  • Received:2013-09-24 Online:2015-02-01 Published:2015-02-06

Abstract:

The concrete plugging of bottom diversion outlet has high proportion of cement, posing big challenge to the temperature control, therefore pipe cooling is needed. In this research, we recommend to combine the heat pipe cooling calculation formula with the measured temperature of concrete block, which means to dynamically update Ti in the heat pipe cooling calculation formula according to the measured temperature, and then predict the dynamic temperature of concrete block of n days in the future to guide and control the pipe cooling. The dynamic prediction for concrete temperature is proved to be feasible by the practical example of concrete temperature of plugging of bottom diversion outlet at Xiangjiaba Hydropower Project.

Key words: bottom diversion outlet, plugging concrete, initial pipe cooling, dynamic prediction, Xiangjiaba hydropower station

CLC Number: