Adhesive Splitting Tensile Strength of Rubberized Concrete Bonded with Ordinary Concrete

MA Ying, REN Xiao-fu, CAO Hong-liang, YUAN Qun, QIAO Lian-peng, WU Huan-huan

Journal of Changjiang River Scientific Research Institute ›› 2018, Vol. 35 ›› Issue (12) : 129-132.

PDF(2247 KB)
PDF(2247 KB)
Journal of Changjiang River Scientific Research Institute ›› 2018, Vol. 35 ›› Issue (12) : 129-132. DOI: 10.11988/ckyyb.20170685
HYDRAULIC STRUCTURE AND MATERIAL

Adhesive Splitting Tensile Strength of Rubberized Concrete Bonded with Ordinary Concrete

  • MA Ying1,2, REN Xiao-fu2,3, CAO Hong-liang1,2, YUAN Qun1,2, QIAO Lian-peng4, WU Huan-huan5
Author information +
History +

Abstract

In the aim of providing theoretical and technical support for the quality and safety of rubberized concrete in engineering application, tests were conducted to investigate the adhesive splitting tensile strength of rubberized concrete bonded with ordinary concrete (RC-OC). The influences of rubber particle size, rubber particle dosage, composite modification and interfacial agent on the adhesive splitting tensile strength of RC-OC were examined.Two different particle sizes of rubber, five different dosages of rubber, and its composite modified rubberized concrete were prepared as new concrete to be poured on ordinary concrete bonded with three different interfacial agents.Results show that the effect of rubber particle size on the adhesive splitting tensile strength of RC-OC varied with the interfacial agent. With the increase of rubber particle dosage, the adhesive splitting tensile strength of RC-OC increased first and then decreased, and reached the maximum at a given dosage of rubber particle. The adhesive splitting tensile strength of both rubberized concrete and ordinary concrete were smaller than that of RC-OC as a whole. Cement paste interfacial agent had remarkable impact on the adhesive splitting tensile strength of both rubberized concrete and ordinary concrete rather than on RC-OC as a whole.Among the three interfacial agents, epoxy interfacial agent could give rise to a largest adhesive splitting tensile strength.Modification on rubber particle size could also enhance the adhesive splitting tensile strength.In summary, modified epoxy interfacial agent has better bonding effect, and could significantly improve the adhesive splitting tensile strength between rubber concrete and ordinary concrete.

Key words

rubberized concrete / adhesive splitting tensile strength / rubber particle size / rubber particle dosage / composite modified rubber / interfacial agent

Cite this article

Download Citations
MA Ying, REN Xiao-fu, CAO Hong-liang, YUAN Qun, QIAO Lian-peng, WU Huan-huan. Adhesive Splitting Tensile Strength of Rubberized Concrete Bonded with Ordinary Concrete[J]. Journal of Changjiang River Scientific Research Institute. 2018, 35(12): 129-132 https://doi.org/10.11988/ckyyb.20170685

References

[1] 潘东平,刘 锋,李丽娟,等.橡胶混凝土的应用及研究概况[J] .橡胶工业,2007,54(3):182-185.
[2] 李晓旭.抗冲磨橡胶混凝土的配制研究与应用[D] .郑州:郑州大学,2015.
[3] 刘 健.新老混凝土粘结的力学性能研究[D] .大连:大连理工大学,2000.
[4] 赵志方,赵国藩,刘 健,等. 新老混凝土粘结抗拉性能的试验研究[J] .建筑结构学报,2001,22(2):51-56.
[5] 韩菊红,赵国藩,张雷顺. 新老混凝土黏结面断裂性能试验研究[J] .土木工程学报,2003,36(6):31-35.
[6] 李平先,张雷顺,赵国藩,等.新老混凝土粘结面渗透性能试验研究[J] .水利学报,2005,36(5):602-607.
[7] 李庚英,谢慧才,熊光晶,等.混凝土修补界面的微观结构及与宏观力学性能的关系[J] .混凝土,1999,(6):13-18.
[8] 赵志方,周厚贵,袁 群,等.新老混凝土粘结机理研究与工程应用[M] .北京:中国水利水电出版社,2003.
[9] 袁 群,冯凌云,袁 宾,等.橡胶颗粒粒径和掺量对混凝土性能的影响[J] .人民黄河,2013.35(2):111-113.
[10] 冯凌云,袁 群,马 莹,等.橡胶混凝土力学性能研究[J] .长江科学院院报,2015.32(7):115-118.
[11] 李 伟,盖玉杰,王晓初.橡胶混凝土的力学性能试验[J] .东北林业大学学报,2009,37(4):63-64.
PDF(2247 KB)

Accesses

Citation

Detail

Sections
Recommended

/