Applicability of Heat Transfer Model of Energy Pile with BuriedSpiral Pipe and Its Experimental Verification

ZHAO Hai-feng,GUI Shu-qiang,TANG Rong-bin,DU Jin-long

Journal of Changjiang River Scientific Research Institute ›› 2017, Vol. 34 ›› Issue (4) : 111-116.

PDF(2878 KB)
PDF(2878 KB)
Journal of Changjiang River Scientific Research Institute ›› 2017, Vol. 34 ›› Issue (4) : 111-116. DOI: 10.11988/ckyyb.20160098
ROCK SOIL ENGINEERING

Applicability of Heat Transfer Model of Energy Pile with BuriedSpiral Pipe and Its Experimental Verification

  • ZHAO Hai-feng1,2,GUI Shu-qiang2,TANG Rong-bin3,DU Jin-long2
Author information +
History +

Abstract

Accuracy of heat transfer model is directly related to the computational accuracy of heat transfer efficiency of energy pile, which influences the design of energy piles. Taken energy pile with buried spiral pipe as the research object, an in-situ test was conducted in Xinyang area, Henan province. Then, measured data such as temperature field around the pile was acquired, and calculation results of the cylindrical heat source model and the coil heat source model are respectively compared with measured data. Research results show that the computational accuracy of heat source model with finite length is higher than that of heat source model with infinite length. Coil heat source model with finite length is more accurate than cylindrical surface heat source model with finite length. The calculation error of tube wall temperature in coil heat source model with finite length is less than 1.5%, the calculation error of temperature field around the pile is less than 2.5%, and the water temperature at inlet and outlet of buried pipe less than 2.2%, respectively. In view of this, coil heat source model with finite length is recommended for calculating temperature field in energy pile with spiral buried tube. The applicability of different heat transfer models for the spiral pipe pile was explored, and can be taken as reference for the design of energy pile with buried spiral tube.

Key words

energy pile with buried spiral pipe / cylindrical heat source model / coil heat source model / temperature field around pile / temperature field around the energy pile / experimental verification

Cite this article

Download Citations
ZHAO Hai-feng,GUI Shu-qiang,TANG Rong-bin,DU Jin-long. Applicability of Heat Transfer Model of Energy Pile with BuriedSpiral Pipe and Its Experimental Verification[J]. Journal of Changjiang River Scientific Research Institute. 2017, 34(4): 111-116 https://doi.org/10.11988/ckyyb.20160098

References

[1] BRANDL H. Thermo-active Ground-Source Structures for Heating and Cooling[J]. Procedia Engineering, 2013,57(1): 9-18.
[2] 桂树强,程晓辉,张志鹏. 地源热泵桩基与钻孔埋管换热器换热性能比较[J]. 土木建筑与环境工程, 2013,35(3): 151-156.
[3] 方肇洪, 刁乃仁, 曾和义. 地热换热器的传热分析[J]. 工程热物理学报, 2004,25(4): 685-687.
[4] 余乐渊,赵 军,李新国,等.竖埋螺旋管地热换热器理论模型及实验研究[J].太阳能学报,2004,25(5):690-694.
[5] 张文克.桩埋管地热换热器的传热模型研究[D].济南:山东建筑大学,2009.
[6] 刘俊红,张克文,方肇洪.桩埋螺旋管式地热换热器的传热模型[J].山东建筑大学学报,2010,25(2):95-100.
[7] 张克文,刘俊红,黄体士,等.桩埋管地热换热器的传热分析[J].制冷与空调,2009,23(4):105-108.
[8] MAN Y, YANG H X, DIAO N R, et al. A New Model and Analytical Solutions for Borehole and Pile Ground Heat Exchangers[J]. International Journal of Heat and Mass Transfer, 2010, 53(13/14): 2539-2601.
[9] 李 新,方 亮,赵 强,等. 螺旋埋管地热换热器的线圈热源模型及其解析解[J]. 热能动力工程, 2011,26(4): 475-479.
[10]李 新.能量桩的传热研究与工程应用[D]. 济南:山东建筑大学, 2011.