JOURNAL OF YANGTZE RIVER SCIENTIFIC RESEARCH INSTI ›› 2011, Vol. 28 ›› Issue (11): 52-56.

• ENGINEERING HYDRAULICS • Previous Articles     Next Articles

Causes and Eliminating Measures of Vortices at the Intake of Short Culvert Conveyance System of Shiplock

WU Ying-Zhuo1, JIANG Yao-Zu1, ZHOU Chi1, JIANG Xiao-Min2   

  1. 1. Yangtze River Scientific Research Institute, Wuhan 430010, China; 2.Changjiang Institute of Survey, Planning, Design and Research, Wuhan 430010, China
  • Online:2011-11-02 Published:2011-11-15

Abstract: Physical model tests were performed to discuss the causes of vortices at the intake of short culvert conveyance system of the shiplock at Xinglong hydro-junction. Effects of the operating mode of the water valve, the submerged water depth at the intake, and the intake shape and solid boundary conditions on the vortex pattern were analyzed. By comparing a series of model tests, measures of properly increasing the submerged water depth at the intake while setting vortex plate at the top of the intake were finally proposed to eliminate the air-inhaling vortices. It provided basis for the optimal design and operation management and could be referential for the design of alike projects.

Key words: shiplock, short culvert conveyance system, vortex at the intake, causes of vortex and eliminating measures

CLC Number: