长江科学院院报 ›› 2014, Vol. 31 ›› Issue (8): 93-97.DOI: 10.3969/j.issn.1001-5485.2014.08.0182014,31(08):93-97

• 水工结构与材料 • 上一篇    下一篇

脉动压力谐响应和时程分析的差异性研究

刘建,伍鹤皋   

  1. 武汉大学 水资源与水电工程科学国家重点实验室, 武汉 430072
  • 收稿日期:2013-12-18 修回日期:2014-08-12 出版日期:2014-08-01 发布日期:2014-08-12
  • 通讯作者: 伍鹤皋(1964-),男,江西宜丰人,教授,研究方向为水电站压力管道与厂房结构,(电话)13808691481(电子信箱)wbf1988@vip.sina.com。
  • 作者简介:刘 建(1986-),男,山东潍坊人,硕士研究生,研究方向为水电站压力管道与厂房结构,(电话)15972223997(电子信箱) 940505123@qq.com。
  • 基金资助:
    国家自然科学基金资助项目(51179141)

Differences between Harmonic Response Analysis and Time-historyAnalysis of Pressure Fluctuation

LIU Jian, WU He-gao   

  1. State Key Laboratory of Water Resources and Hydropower Engineering Science,Wuhan University, Wuhan 430072, China
  • Received:2013-12-18 Revised:2014-08-12 Online:2014-08-01 Published:2014-08-12

摘要: 谐响应分析和时程分析是研究水电站厂房结构在脉动压力作用下的振动响应时最常用的2种方法。为分析2种方法的差异性,采用谐响应分析法和时程分析法计算了同一抽水蓄能电站厂房结构在脉动压力作用下的振动响应。对2种方法计算的厂房结构振幅、振动速度、振动加速度和动应力进行对比分析,从而分析2种计算方法的差异性。结果表明:采用谐响应分析法计算的振幅、振动速度和振动加速度的均方根值大于时程分析的计算结果,但峰值小于时程分析的计算结果;厂房结构动应力数值不大,两者的计算结果差别不大。能够获得脉动压力时程资料时,应尽量采用时程分析法计算动力响应;缺乏脉动压力时程资料时,谐响应法也可用来分析动力响应。

关键词: 谐响应分析, 时程分析, 脉动压力, 水电站厂房, 动力响应

Abstract: Harmonic response analysis and time history analysis are both most commonly used to analyze the vibration responses of powerhouse structure. In order to analyze the differences between these two methods, we calculated the vibration responses of powerhouse structure of a pumped storage station under pressure fluctuations using the two methods. By comparing the vibration amplitude, vibration speed, vibration acceleration and dynamic stresses of powerhouse structure, we obtained the differences between these two methods. Results suggest that the root mean square values of vibration amplitude, vibration speed and acceleration calculated by harmonic response analysis are bigger and peak values are smaller than those calculated by time history analysis. The dynamic stress of powerhouse structure calculated by the two methods are both small and the difference between the results is also small. When the time-history data of pressure fluctuation is available, time history analysis method is preferable; if not, harmonic method can also be used to analyse the dynamic responses of powerhouse structure.

Key words: harmonic response analysis, time history analysis, pressure fluctuation, powerhouse structure, dynamic response

中图分类号: