Numerical research on the orifice-plate of a powerplant was carried out to analyse the discharge coefficient and pressure distribution at different sections. Results shows that the pressure measurement holes should be set at positions with the maximum pressure in the upstream and minimum pressure in the downstream. The downstream pressure measurement hole should be set at a distance 0.3D to 0.5D away from the plate center; while the upstream pressure measurement hole should be set at a distance 0.5D to 1.5D away from the plate center. Since the distance between the pressure measurement holes could seriously affect the measurement accuracy of flow rate, the installation of the orifice-plate flowmeter must be in strict accordance with the size of pressure hole, and the discharge coefficient should be corrected according to the actual position of measurement holes. There were obvious reflux at the downstream of the typical section, and the reflux flow rate accounted for 15% of the total flow rate. This research could provide reference for the pressure measurement, installation, test and adjustment of orifice-plate flowmeter.
LI Zhi-hua
,
CHEN Shao-hua
,
CHEN Kun
,
ZHAO Ya-ping
. Numerical Research on the Performance of Differential Pressure
Orifice-plate Flowmeter[J]. Journal of Changjiang River Scientific Research Institute, 2014
, 31(12)
: 129
-134
.
DOI: 10.3969/j.issn.1001-5485.2014.12.026
[1]李志华.轴流转桨式水轮机过流部件的匹配与数值模拟[D].西安:西安理工大学,2010. (LI Zhi-hua. Machine of Flow-Parts and Numerical Simulation for Kaplan Turbine[D]. Xi’an: Xi’an University of Technology, 2010. (in Chinese))
[2] 张凌飞.离心泵内部流场三维数值模拟[D].北京:中国农业大学,2007. (ZHANG Ling-fei. Numerical Simulation of Flow in Centrifugal Pump[D]. Beijing: China Agricultural University, 2007. (in Chinese))
[3] GBT 2624.1,用安装在圆形截面管道中的差压装置测量满管流体流量[S].北京,中国标准出版社,2006. (GBT 2624.1, Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-section Conduits Running Full[S]. Beijing: Chinese Standards Press,2006. (in Chinese))
[4] GBT 2624.2,用安装在圆形截面管道中的差压装置测量满管流体流量[S]. 北京:中国标准出版社,2006. (GBT 2624.2, Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-section Conduits Running Full[S]. Beijing: Chinese Standards Press,2006. (in Chinese))
[5] 廖伟丽,赵亚萍,李志华,等.不同支墩的蜗壳对水轮机流场特性及性能的影响[J].水力发电学报,2012,31(2):210-215.(LIAO Wei-li, ZHAO Ya-ping, LI Zhi-hua, et al. Effect of Different Buttress Scroll on the Characteristics and Performance of Turbine Flow Field[J]. Journal of Hydroelectric Engineering, 2012,31(2): 210-215. (in Chinese))