JOURNAL OF YANGTZE RIVER SCIENTIFIC RESEARCH INSTI ›› 2015, Vol. 32 ›› Issue (7): 109-114.DOI: 10.3969/j.issn.1001-5485.2015.07.020

• HYDRAULIC STRUCTURE AND MATERIAL • Previous Articles     Next Articles

Nonlinear Contact Analysis on the Spiral Case Composite Structure in Pumped Storage Power Station

WEI Bo-wen1,2, WANG Feng1, XU Zhen-kai1, JIANG Zhen-xiang1   

  1. 1.College of Civil Engineering and Architecture, Nanchang University, Nanchang 330031, China;
    2.College of Water Conservancy and Hydropower Engineering, Hohai University, Nanjing 210098, China
  • Received:2013-12-18 Online:2015-07-01 Published:2015-07-07

Abstract: A new contact element model used for the interface of different materials is introduced to conduct nonlinear contact analysis on the spiral case structure of a hydropower station based on ABAQUS procedure. The mechanics behavior of preloading filling spiral case in pumped storage unit and the contact force transmission between steel spiral case and its surrounding concrete are considered. The calculation result is compared with finite element calculation result and measured data. Result reveals that the calculation results of contact element model is consistent with measured data and accords with engineering practice. The real mechanics behavior of the spiral case composite structure is revealed effectively and the appropriateness of contact element model is verified. In addition, it provides reliable scientific foundation for the optimization design of spiral case structure.

Key words: hydropower station, spiral case, water filling pressurization, contact analysis, ABAQUS

CLC Number: