Comparison of Second Stage Artificial Cooling Schemes in Xia owan Arch Dam

ZHOU Yan-Guo, WANG Jiang, XU Han

Journal of Changjiang River Scientific Research Institute ›› 2009, Vol. 26 ›› Issue (7) : 48-51.

PDF(2053 KB)
PDF(2053 KB)
Journal of Changjiang River Scientific Research Institute ›› 2009, Vol. 26 ›› Issue (7) : 48-51.
.

Comparison of Second Stage Artificial Cooling Schemes in Xia owan Arch Dam

  •  ZHOU  Yan-Guo, WANG  Jiang, XU  Han
Author information +
History +

Abstract

Cooling concrete in different stages in different schemes of water pipe cooling is one of the important temperature control measures in the construction of the high arch dam, and the comparison of two ways of second stage artificial cooling in Xiaowan arch dam is presented. The study result shows that: with the scheme of direct second stage artificial cooling, the temperature gratitude may be so biggish that the tensile stress appears in certain elevation of the dam; with the way of transitional second stage artificial cooling, the temperature gratitude can be decreased effectively and the tensile stress in the dam can be eliminated somewhat. Obviously, through the comparison of two kinds of artificial cooling schemes, the later is better than the fomer. In construction practice, the transitional second stage cooling scheme has received good effect.

Cite this article

Download Citations
ZHOU Yan-Guo, WANG Jiang, XU Han. Comparison of Second Stage Artificial Cooling Schemes in Xia owan Arch Dam[J]. Journal of Changjiang River Scientific Research Institute. 2009, 26(7): 48-51