Model Test of Mud-Intercalated Bored Pile Detection Based onOptical Fiber Sensing Technology

FAN Meng, LEI Wen-kai, XIAO Heng-ling, LIU Yong-li

Journal of Changjiang River Scientific Research Institute ›› 2016, Vol. 33 ›› Issue (4) : 95-98.

PDF(920 KB)
PDF(920 KB)
Journal of Changjiang River Scientific Research Institute ›› 2016, Vol. 33 ›› Issue (4) : 95-98. DOI: 10.11988/ckyyb.20150095
ROCK-SOIL ENGINEERING

Model Test of Mud-Intercalated Bored Pile Detection Based onOptical Fiber Sensing Technology

  • FAN Meng1,2, LEI Wen-kai3, XIAO Heng-ling1, LIU Yong-li1
Author information +
History +

Abstract

The principle of bored pile detection based on distributed optical fiber sensing technology is introduced in this paper and model test is carried out. Mud-intercalated bored piles with different clay contents (0, 33.3%, 50%, 66.7%, 100%) are prepared, and the optical fiber temperature rise in these piles are measured to analyzethe rule of the temperature rise as well as the influences of heating power and clay content on optical fiber temperature rise. The results reveal a good linear relationship between heating power and optical fiber temperature rise. The temperature rise increases slowly firstly and then rapidly with the increment of clay content. It is also closely related with the structure and heat conductivity coefficient of pile medium. The model test in this paper verifies the feasibility of distributed optical fiber sensing technology in the detection of bored pile foundation.

Key words

optical fiber sensing technology / pile foundation detection / mud-intercalated pile / temperature rise / bored pile

Cite this article

Download Citations
FAN Meng, LEI Wen-kai, XIAO Heng-ling, LIU Yong-li. Model Test of Mud-Intercalated Bored Pile Detection Based onOptical Fiber Sensing Technology[J]. Journal of Changjiang River Scientific Research Institute. 2016, 33(4): 95-98 https://doi.org/10.11988/ckyyb.20150095

References

[1] 张 宏.灌注桩检测与处理.北京:人民交通出版社,2001.
张献民,蔡 靖,王建华.基桩缺陷量化低应变动测研究.岩土工程学报,2003,25(1):47-50.
陈 凡,徐天平,陈久照,等.基桩质量检测技术.北京:中国建筑工业出版社,2003.
张 丹,施 斌,吴智深.BOTDR分布式光纤传感器及其在结构健康监测中的应用.土木工程学报,2003,36(11):83-87.
MERZBACHER C I, KERSEY A D, Fiber Optic Sensors in Concrete Structures: A Review. Smart Material Structure, 1995, 5(2): 196-208.
江 宏.PPP-BOTDA分布式光纤传感技术及其在试桩中应用.岩土力学,2011,32(10):3190-3195.
朴春德,施 斌,魏光庆,等.分布式光纤传感技术在钻孔灌注桩检测中的应用.岩土工程学报,2008,30(7):976-981.
宋建学,白翔宇,任慧志.分布式光纤在基桩静载荷试验中的应用.河南大学学报(自然科学学报),2011,41(4):429-432.
肖衡林,张晋峰,何 俊.基于分布式光纤传感技术的流速测量方法研究.岩土力学,2009, 30 (11):3543-3547.
肖衡林,鲍 华,何 俊.分布式光纤温度传感技术在水电工程中的应用研究.长江科学院院报,2009, 26(10):104-107.