岩土工程

码头堆场地基强夯加固对邻近铁路桥振动影响的研究

  • 丁圣辉 ,
  • 丁淑平 ,
  • 张明强
展开
  • 1.湖北工程学院 土木工程学院,湖北 孝感 432000;
    2.长江勘测规划设计研究院 a.长江岩土工程总公司;b.市政与交通院,武汉 430010
丁圣辉(1995-),男,湖北荆州人,本科在读,主要从事土木工程道路桥梁方面的研究。E-mail:2569052715@qq.com

收稿日期: 2018-03-13

  修回日期: 2018-04-02

  网络出版日期: 2018-06-16

Influence of Dynamic Compaction of Wharf Yard Foundation on the Vibration of Adjacent Railway Bridges

  • DING Sheng-hui ,
  • DING Shu-ping ,
  • ZHANG Ming-qiang
Expand
  • 1.School of Civil Engineering, Hubei Engineering University,Xiaogan 432000, China;
    2.Changjiang Geotechnical Engineering Corporation, Changjiang Institute of Survey, Planning, Design and Research, Wuhan 430010, China;
    3.Municipal and Traffic Engineering Department, Changjiang Institute of Survey, Planning, Design and Research, Wuhan 430010, China

Received date: 2018-03-13

  Revised date: 2018-04-02

  Online published: 2018-06-16

摘要

武汉港花山码头工程陆域堆场位于铁路专用线通过区域。为研究陆域堆场强夯对邻近铁路桥的影响,合理确定强夯工艺,结合强夯试验成果分析了夯能、夯击数、夯击距离与铁路桥振动之间的关系。现场测试采取4 500 kN·m夯能时,强夯击数>5击后铁路桥桥面振动速度收敛至3.5 cm/s。采取6 000 kN·m夯能时,40 m以外的铁路桥桥面振动速度<4.0 cm/s,振动频率<10 Hz,满足《建筑工程容许振动标准》要求。依据试验成果推导出了黏土地基强夯引起的建筑物振动速度衰减规律方程,相关研究成果可为同类工程借鉴参考。

本文引用格式

丁圣辉 , 丁淑平 , 张明强 . 码头堆场地基强夯加固对邻近铁路桥振动影响的研究[J]. 长江科学院院报, 2018 , 35(6) : 98 -101,106 . DOI: 10.11988/ckyyb.20180238

Abstract

The land yard of Huashan wharf project of Wuhan Port is located in railway line area. To investigate into the influence of dynamic compaction on adjacent railway bridge, hence determining a reasonable compaction technique, we analyzed the relationship between tamping energy, tamping number, tamping distance and railway bridge vibration according to field compaction test.In field test,the vibration velocity of bridge floor converged to 3.5 cm/s when dynamic tamping energy was 4 500 kN·m after tamping number reached 5; the vibration velocity of bridge floor was smaller than 4.0 cm/s and vibration frequency less than 10 Hz when tamping energy amounted to 6 000 kN·m beyond 40 m, which meets the requirements of Standard for Allowable Vibration of Building Engineering. In addition, the equation of vibration velocity attenuation of buildings caused by clayey foundation compaction was deduced based on test results for reference for similar projects.

参考文献

[1] 杭的平,韩云山.强夯振动影响的研究. 四川建筑,2014,34(1):71-72.
[2]郑俊杰.地基处理技术.2版.武汉:华中科技大学出版社,2009.
[3]尚军雷,徐 风,王韶光.施工振动对邻近建筑的危害.防灾技术高等专科学校学报,2006,8(2):82-85.
[4]罗辉才,王喜迁.强夯振动测试及隔振沟减振效果实例分析.云南地质,2011,30(4):471-475.
[5]方 磊,经 绯,刘松玉.强夯振动影响与构筑物安全距离研究.东南大学学报(自然科学版),2001,31(3):29-32.
[6]安惠泽,许兆义,冯瑞玲.某站场地基强夯振动影响范围研究.北京交通大学学报,2010,34(2):50-52.
[7]CECS 279—2010,强夯地基处理技术规程.北京:中国计划出版社,20l0.
[8]GB 50868—2013,建筑工程容许振动标准. 北京:中国计划出版社,2013.