水工结构与材料

有限元模拟FRP筋混凝土双向板的冲切过程

  • 侯黎黎 ,
  • 张亚坤
展开
  • 1.黄河水利职业技术学院,河南 开封 475004;
    2.小流域水利河南省高校工程技术研究中心,河南 开封 475004
侯黎黎(1984-),男,河南登封人,助教,硕士,主要从事水工材料及其结构安全性研究,(电话)13783459239(电子信箱)houlilixiaodan@163.com。

收稿日期: 2013-04-01

  修回日期: 2014-05-12

  网络出版日期: 2014-05-12

Finite Element Simulation on the Punching Process of FRP Reinforced Concrete Two-way Slabs

  • HOU Li-li ,
  • ZHANG Ya-kun
Expand
  • 1.Yellow River Conservancy Technical Institute, Kaifeng 475004, China;
    2.Engineering Technology Research Center of Small Watershed Conservancy under Universities of Henan Province, Kaifeng 475004, China

Received date: 2013-04-01

  Revised date: 2014-05-12

  Online published: 2014-05-12

摘要

为了探索运用有限元分析法研究集中荷载作用下纤维增强塑料(Fiber Reinforced Polymer,FRP)筋混凝土双向板的冲切受力性能的可行性,运用ANSYS软件建立了FRP筋混凝土双向板的有限元模型,并模拟了FRP筋混凝土双向板在集中荷载作用下从加载开始到发生冲切破坏的整个受力过程,得到了FRP筋混凝土板ANSYS分析的荷载-挠度(P-w)曲线,并将其与偏置集中荷载作用下FRP筋混凝土双向板的冲切试验研究所得P-w曲线进行对比分析。对比成果表明:ANSYS分析P-w曲线与试验P-w曲线吻合较好,在研究FRP筋混凝土双向板的冲切破坏机理时,运用ANSYS软件模拟分析替代部分冲切试验研究是行之有效的新途径。对FRP筋混凝土双向板冲切受力过程的P-w曲线进行分析,得知集中荷载作用下FRP筋混凝土双向板的破坏是发生在板局部的脆性破坏,混凝土强度、筋材、配筋率、荷载位置等因素是影响P-w曲线形状、最高点、曲线斜率的主要因素。

本文引用格式

侯黎黎 , 张亚坤 . 有限元模拟FRP筋混凝土双向板的冲切过程[J]. 长江科学院院报, 2014 , 31(5) : 87 -91 . DOI: 10.3969/j.issn.1001-5485.2014.05.018

Abstract

In this research, we explored the feasibility of using finite element method to research the punching shear performance of FRP (Fiber Reinforced Polymer) bar reinforced concrete two-way slab under concentrated loads. The finite element model of FRP bar concrete two-way slabs was established by using ANSYS software, and the slab’s punching shear failure process was simulated. The P-w curves (load-deflection curves) in ANSYS simulation were obtained and were further compared with curves obtained from offset concentrated load tests. Results revealed that the simulation curves were in good agreement with test curves, which indicated that ANSYS simulation in substitution of partial punching shear tests is feasible. Furthermore, analysis on the P-w curves showed that the punching failure of FRP bar concrete two-way slab under concentrated load is a local brittle failure, and concrete strength, material, reinforcement ratio, as well as load location are the main factors affecting the shape, highest point, and slope of the P-w curves.

参考文献

[1] 林旭健.钢纤维混凝土板冲切的变形与强度[J].福州大学学报,1999,27(1):70-73.(LIN Xu-jian. Deformation and Strength Behavior of Steel Fiber Reinforced Concrete Slabs Subjected to Punching Shear[J].Journal of Fuzhou University,1999,27(1):70-73.(in Chinese))
[2] 林旭健.钢纤维高强混凝土冲切板的试验研究[D].杭州:浙江大学,1999.(LIN Xu-jian. Research on Steel Fiber High-strength Concrete Slab Subjected to Punching Shear[D]. Hangzhou: Zhejiang University,1999.(in Chinese))
[3] 张亚坤.偏置荷载下FRP筋砼双向板冲切性能研究[D].郑州:郑州大学,2010.(ZHANG Ya-kun. Research on Punching Shear Properties of Concrete Two-way Slabs Reinforced with FRP Bars Subjected to Eccentric Load[D]. Zhengzhou: Zhengzhou University, 2010.(in Chinese))
[4] 张亚坤,朱海堂,侯黎黎. 集中荷载下FRP筋混凝土双向板的冲切受力性能[J].工业建筑,2012,(12):30-34.(ZHANG Ya-kun, ZHU Hai-tang, HOU Li-li. Punching Behavior of Concrete Two-way Slabs Reinforced with FRP Bars under Concentrated Loading[J]. Industrial Construction,2012,(12):30-34.(in Chinese))
[5] 何本国,陈天宇,王 洋.ANSYS土木工程应用实例(第三版)[M].北京:中国水利水电出版社,2011. (HE Ben-guo, CHEN Tian-yu, WANG Yang. Application Examples of ANSYS in Civil Engineering (The Third Edition) [M].Beijing:China Water Power Press, 2011.(in Chinese))
[6] 谢晓鹏.钢筋局部钢纤维混凝土板冲切性能研究[D].郑州:郑州大学,2007.(XIE Xiao-peng. Punching Shear Properties of Concrete Slab with Partially Reinforced High-Strength Steel Fiber[D].Zhengzhou: Zhengzhou University,2007.(in Chinese))
[7] NANNI A. FRP Reinforced for Concrete Structures[J]. Cement and Concrete Composites,1994, 16(1):65-66.
[8] DAVILA M A. Using Fiber Reinforced Plastic (FRP) Reinforcing Bars in RC Beams and Slabs[C]∥Creative Systems in Structural and Construction Engineering: Proceedings of the First International Structural Engineering and Construction Conference, Honolulu, Hawaii, January 24-27, 2001: 473-477.
文章导航

/