大型发电机中性点采用高阻抗配电变压器接地的配置方法

陈渝士 , 陶亦寿

长江科学院院报 ›› 2011, Vol. 28 ›› Issue (9) : 68-70.

PDF(828 KB)
PDF(828 KB)
长江科学院院报 ›› 2011, Vol. 28 ›› Issue (9) : 68-70.
仪器设备与测试技术

大型发电机中性点采用高阻抗配电变压器接地的配置方法

  • 陈渝士 , 陶亦寿
作者信息 +

Configuration of Large Generator Neutral Grounding Through High Impedance Distribution Transformer

  • CHEN Yu-shi, TAO Yi-shou
Author information +
文章历史 +

摘要

大型发电机定子绕组对地电容较大,发生定子单相接地故障时电容电流也较大,采用中性点经配电变压器接地方式,能起到对过大故障电流限制的作用。采用高阻抗变压器作为中性点接地变压器的配置方法,利用变压器内在电抗生成的电感性电流,对故障电容电流进行部分补偿,在满足抑制故障暂态过电压要求的同时,将接地故障电流限制在允许范围内,解决了配置大型发电机中性点接地装置中常见的接地故障电流过大问题。

Abstract

The excessive fault current induced by stator single-phase earth fault and big ground capacitance of stator winding of large generator can be restricted by neutral grounding through distribution transformer. This paper introduces a configuration method of generator neutral grounding device with high impedance distribution transformer. The fault capacitive current is partly compensated by the inductive current generated from the internal reactance of the transformer, and the ground-fault current is limited within an allowable range while the fault transient overvoltage is restrained.

关键词

发电机中性点  / 接地装置  / 高阻抗变压器  / 配置方法

Key words

generator neutral /    grounding device /    high impedance transformer  /  configuration method

引用本文

导出引用
陈渝士 , 陶亦寿. 大型发电机中性点采用高阻抗配电变压器接地的配置方法[J]. 长江科学院院报. 2011, 28(9): 68-70
CHEN Yu-shi, TAO Yi-shou. Configuration of Large Generator Neutral Grounding Through High Impedance Distribution Transformer [J]. Journal of Changjiang River Scientific Research Institute. 2011, 28(9): 68-70