未加载充分的现场静载荷试验不能完全反映地基承载力情况,有可能导致复合地基安全储备过高。结合闽东沿海某工程,在静载荷试验未加载充分的情况下,利用灰色模型预测了单桩和复合地基的极限承载力。同时,定义复合地基承载力极限值与按相对变形确定的特征值之比为K,K是一个反映复合地基承载力安全储备的安全系数。通过统计同地区113组复合地基静载荷试验结果,确定了水泥土搅拌桩复合地基的K值。经过验证,K值同样适用于该工程。因此K具有一定地区性,在根据相对变形确定复合地基承载力特征值后,利用K可以一定程度上预测复合地基承载力极限值,从而为较直观认知复合地基的安全储备提供参考。
Abstract
In some projects there are restrictions in static loading tests and thus the characteristic load bearing capacity is unable to be determined. Through analyzing a project of cement-soil pile composite foundation, the ultimate bearing capacity of the piles and composite foundation is predicted with “gray model” under limited test conditions. Meanwhile, the ratio of the bearing capacity to the characteristic bearing capacity determined from relative deformation is defined as safety reserve index “K”, and 113 groups of static loading test are analyzed to obtain the K value of this region. The statistical result is confirmed by the project. It should be noticed that K is a regional and experiential value, and it can be used to predict the ultimate bearing capacity of cement-soil pile composite foundation based on the known bearing capacity determined by relative deformation.
关键词
水泥土搅拌桩 /
静载荷试验 /
复合地基承载力 /
安全系数 /
灰色模型
Key words
cment-soil piles /
static loading test /
bearing capacity of composite foundation /
safety reserve /
gray model
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] NICOLA A D, RANDOLPH M F. Tensile and Compressive Shaft Capacity of Piles in Sand[J]. Journal of Geotechnical Engineering, 1995, 119(12): 1952-1973.
[2] KHING K H, DAS B M,PURI V K,et al. The Bearing-capacity of a Strip Foundation on Geogrid-reinforced Sand[J]. Geotextiles & Geomembranes, 1993, 12(4): 351-361.
[3] BOLTOM M D, LAU C K. Vertical Bearing Capacity Factors for Circular and Strip Footings on Mohr-Coulomb Soil[J]. Canadian Geotechnical Journal, 1993, 30(6): 1024-1033.
[4] BOUSHEHRIAN J H, HATAF N. Experimental and Numerical Investigation of the Bearing Capacity of Model Circular and Ring Footings on Reinforced Sand[J]. Geotextiles & Geomembranes, 2003, 21(21): 241-256.
[5] HWANG J H, FU Z X, YEH P Y, et al. Axial Bearing Behaviour of a Model Pile in Sand under Multiple Static Cycles[J]. Geotechnical Engineering, 2014, 45(2): 52-61.
[6] KUMAR J, CHAKRABORTY M.Bearing Capacity Factors for Ring Foundations[J].Journal of Geotechnical & Geoenvironmental Engineering,2015,141(10):066015007.doi:10.1061/(ASCE)GT.1943-5606.0001345.
[7] 黄春霞,张鸿儒,桂国庆.水泥土搅拌桩复合地基承载力公式中折减系数β取值的分析[J].工程地质学报,2003, 11(4):385-389.
[8] 林奕禧,张伟丽,黄良机,等.水泥土搅拌桩复合地基承载力折减系数α和β的试验研究[J].岩石力学与工程学报,2009, 28(增2):3815-3820.
[9] 付文光.一种用桩土载荷试验结果计算复合地基承载力的方法[J].岩土工程学报,2013,35(增2):592-595.
[10]马克生,梁仁旺,白晓红.水泥搅拌桩复合地基承载力的试验确定[J].岩石力学与工程学报,2004,23(15):2652-2654.
[11]张 蕾.原位载荷试验确定复合地基承载力方法研究[J].岩土力学,2014,35(增2):240-244.
[12]JGJ 79—2012,建筑地基处理技术规范[S]. 北京:中国建筑工业出版社,2013.
[13]李小芳,陆培毅.深层搅拌复合地基的极限承载力预测模型探讨[J].岩土力学,2004,25(2):327-329.
[14]戚科骏,徐美娟,宰金珉.单桩承载力的灰色预测方法[J].岩石力学与工程学报,2004,23(12):2069-2071.
[15]罗战友,董清华,龚晓南.未达到破坏的单桩极限承载力的灰色预测[J].岩土力学,2004,25(2):304-307.
[16]YANG F, SUN L Z, XIE Z L, et al. Influence of Grey System Parameter Identification Method on Prediction of Bearing Capacity of Piles[J]. The ACS Journal of Surfaces & Colloids, 2011, 243/249(6): 2044-2049.
[17]许晶菁,陈颖辉,鲁忠军,等.柔性桩的Q-s曲线的拟合[J].工业建筑,2006,36(增1):697-700.
[18]GB/T 50783—2012, 复合地基技术规范[S].北京:中国计划出版社,2012.
[19]徐 超,叶观宝.水泥土搅拌桩复合地基的变形特性与承载力[J].岩土工程学报,2005,27(5):600-603.
[20]蔡来炳.福州地区水泥土搅拌桩复合地基承载特性的研究[J].建筑结构,2003,(3):7-9.
[21]王成锋,刘 宏,高振鲲.载荷试验确定水泥土搅拌群桩复合地基承载力[J].路基工程,2008,(4):155-157.
[22]黄春霞,韩爱民,隋志龙,等.水泥土搅拌桩复合地基承载力的确定[J].水文地质工程地质,2009,36(3):99-102.
[23]孙广灿.水泥土搅拌桩群桩复合地基承载力确定方法的分析与研究[D].太原:太原理工大学,2010.