Discussion on the Application of Free Oscillation Test in Stratum Permeability Evaluation

  • CUI Zhong-tao ,
  • XU Hai-yang ,
  • GUO Jin-song
Expand
  • Power China Chengdu Engineering Corporation Limited, Chengdu 610072, China

Received date: 2014-07-31

  Revised date: 2014-08-02

  Online published: 2015-04-21

Abstract

Free oscillation test is a hydro-geological test which adopts excitation method to make an instantaneous change in borehole water level. Through the test process the water level-time response data will be measured and thus to determine the permeability coefficient of the aquifer stratum. This test has been applied in many engineering projects for stratum permeability evaluation and has an efficient result. Air pressure is usually adopted to excite the water head, while water injection is convenient to excite water head only by injecting a certain amount of water. It needs less equipment and operates easily. In this research we conducted a free oscillation test with water injection method to evaluate the stratum permeability coefficient and compared the advantages and shortcomings of various test methods (gas pressure and standard water pumping and injection). We found that free oscillation test with water injection method is the most convenient, however, some part of the test data revealed deviations rather than the results derived from the standard water pumping test. We analyzed the causes of the deviation and put forward improvements to demonstrate the feasibility of this test method with the expectation to verify the improved method and achieve popularization of this test method in hydropower station projects.

Cite this article

CUI Zhong-tao , XU Hai-yang , GUO Jin-song . Discussion on the Application of Free Oscillation Test in Stratum Permeability Evaluation[J]. Journal of Changjiang River Scientific Research Institute, 2015 , 32(4) : 77 -80 . DOI: 10.3969/j.issn.1001-5485.2015.04.015

References

[1] 沈珍瑶, 谢彤芳. 确定含水层渗透系数的微水试验法[J].地下水, 1994, 16 (1): 4-5. (SHEN Zhen-yao, XIE Tong-fang. Slug Test to Determine Permeability Coefficient of Aquifer. Groundwater, 1994, 16(1): 4-5. (in Chinese))
BROWN D L, NARASIMHAN T N, DEMIR Z. An Evaluation of the Bouwer and Rice Method of Slug Test Analysis. Water Resources Research, 1995, 31 (5): 1239-1246.
AUDOUIN O, BODIN J. Analysis of Slug Tests with High-frequency Oscillations. Hydrology, 2007, 334: 282-289.
BOUWER H. The Bouwer and Rice Slug Test: An Update. Groundwater, 1989, 27(3): 304-309.
BOUWER H. Discussion of Bouwer and Rice Slug Test Review Articles. Groundwater, 1996, 34(1): 171.
NEUMAN S P. Effect of Partial Penetration on Flow in Unconfined Aquifers Considering Delayed Gravity Response. Water Resources Research, 1974, 10(2): 303-312.
盛焕鸿,王雪梅,姜淑珍,等. 自振法抽水试验与地下水长观监测系统 .成都:中国水电建设顾问集团成都勘测设计研究院, 1994.(SHENG Huan-hong,WANG Xue-mei,JIANG Shu-zhen, et al. Self-vibration Pumping Test and the Groundwater Monitoring System. Chengdu: Power China Chengdu Engineering Corporation Limited, 1994. (in Chinese))
魏 华,何立新. 自振法模拟试验报告 . 成都: 中国水电建设顾问集团成都勘测设计研究院, 1995. (WEI Hua, HE Li-xin. Report of Self-vibration Simulation Test. Chengdu: Power China Chengdu Engineering Corporation Limited, 1995. (in Chinese))
曾新翔. 岩土体渗透性参数现场快速测试系统开发与应用[D].南京:河海大学, 2009. (ZENG Xin-xiang. Development and Application of Rock and Soil Permeability Parameters of On-site Rapid Test. Nanjing: Hohai University, 2009. (in Chinese))
BOUWER H, RICE R C. A Slug Test for Determining Hydraulic Conductivity of Unconfined Aquifers with Completely or Partially Penetrating Wells. Water Resources Research, 1976, 12(3): 423-428.
KENNETH L. KIPP JR. Type Curve Analysis of Inertial Effects in the Response of a Well to a Slug Test. Water Resources Research, 1985, 21(9): 1397-1408.