0 引言
1 模型试验介绍
1.1 试验黄土基本物性
表1 试验黄土的基本物理性质指标Table 1 Basic physical properties of test loess |
| 天然湿密度ρ/ (g·cm-3) | 天然含水率 w(%) | 孔隙比e | 相对密度Gs |
|---|---|---|---|
| 1.62 | 13.21 | 0.996 | 2.70 |
| 最大干密度 ρdmax/(g·cm-3) | 最优含水率 wopc/% | 曲率系数 Cc | 不均匀系 数Cu |
| 1.74 | 15.8 | 1.508 | >5 |
高温作用下封闭土柱水汽迁移规律试验研究
|
胡梦玲(1985-),女,湖北黄冈人,副教授,博士,主要从事非饱和土力学和路基长期稳定性方面的研究工作。E-mail:mlhu5566@163.com |
Copy editor: 王 慰
收稿日期: 2024-09-04
修回日期: 2024-11-28
网络出版日期: 2025-01-23
基金资助
国家自然科学基金项目(41702346)
陕西省自然科学基础研究计划项目(2022JM-287)
岩土力学与工程安全全国重点实验室开放基金课题(SKLGME023021)
Experimental Study on Water Vapor Migration Patterns of Sealed Soil Columns under High-Temperature Conditions
Received date: 2024-09-04
Revised date: 2024-11-28
Online published: 2025-01-23
近年来,极端气候事件频发,西北地区夏季昼夜温差加剧,白天高温持续时间延长,导致水汽迁移对路基湿度的影响愈加显著。采用自制的一维土柱模型试验装置,开展了边界加热条件下黄土土柱的水汽迁移试验,分析了昼夜温差循环与持续加热2种高温作用方式下一维封闭土柱的水汽迁移规律,并探讨了不同加热作用对土柱温湿度分布特性的影响。结果表明:在升温阶段,土柱温度沿高度呈线性分布,升温速度先快后慢,且2种加热方式下土柱温度分布最终均趋于稳定。土柱湿度受水分迁移、液态水汽化、气态水迁移及蒸汽压超饱和时的凝结作用等共同影响。2种加热方式下土柱含水率分布呈现反“S”型曲线,昼夜温差循环加热时土柱上部22.5 cm含水率高于持续高温加热。2种加热方式下土柱湿度均能达到平衡状态。
胡梦玲 , 陈豪 , 王治文 , 郜可欣 , 宫建华 , 匡智彬 . 高温作用下封闭土柱水汽迁移规律试验研究[J]. 长江科学院院报, 2025 , 42(11) : 118 -125 . DOI: 10.11988/ckyyb.20240942
[Objective] In recent years, with frequent extreme climate events, the northwestern region of China has experienced large diurnal temperature difference in summer, with daytime high temperatures continuously rising and persisting for extended periods. The resulting water vapor migration significantly affects the subgrade moisture content, thereby influencing the engineering performance of the subgrade. Investigating the water vapor migration patterns in loess subgrades under sealed pavement structures subjected to high temperatures holds substantial practical significance and application value for scientifically predicting the engineering performance of loess subgrades and ensuring their long-term stability. [Methods] A self-developed one-dimensional soil column test apparatus was employed, with compacted loess columns from the suburbs of Xi’an as the study subjects. The MTD15 temperature and moisture sensors were utilized to monitor the temperature and moisture variations within the loess columns under a boundary heating condition of 55 ℃. The water vapor migration patterns in one-dimensional sealed soil columns were analyzed under two heating modes: diurnal temperature cycling and continuous heating. Furthermore, the effects of different heating modes on the temperature and moisture distribution characteristics of the soil columns were explored. [Results] Boundary heating caused the temperature of the soil columns to rise, with a faster increase in the upper part and a slower increase at the bottom. During the heating phase, the temperature distribution along the height exhibited an approximately linear pattern. Under the cyclic heating of diurnal temperature difference, the internal temperature of the soil columns dropped rapidly after the heating was stopped. The cooling rate in the upper part was significantly higher than that in the middle and lower parts. By 08:00 the next day, the soil column temperature ranged between 22-25 ℃, with the middle part slightly warmer than the two ends. At 20:00 each day and 8:00 the following day, the temperature distribution along the depth of the soil columns remained basically the same. Under continuous heating, the soil column temperature reached dynamic equilibrium after 10 days of heating, exhibiting a two-segment, piecewise linear distribution. The variation trends in the moisture content distribution curves of the soil columns under the two heating methods were basically the same—namely, a decrease in moisture content in the upper part, an increase in the middle, and a decrease in the lower part, with these trends becoming more pronounced as the experiment progressed. However, within the upper 22.5 cm of the soil columns, the moisture content under the cyclic heating of diurnal temperature difference was higher than that under continuous high-temperature heating. [Conclusion] Under boundary heating conditions, the moisture of sealed soil columns is primarily governed by the combined effects of liquid water vaporization and moisture migration within the pores, water vapor migration driven by vapor concentration gradients, and condensation of vapor in the pores when the vapor pressure exceeds the saturated vapor pressure. These mechanisms collectively result in an inverse “S”-shaped moisture distribution. For subgrades with cover layers, 30 days of cyclic heating of diurnal temperature difference during summer induces moisture at 5 cm depth to fluctuate between -2% and +2% of the initial moisture content. This cyclic fluctuation of the upper subgrade moisture induced by diurnal temperature difference will significantly affect the mechanical properties of the subgrade. Under extreme climate conditions characterized by continuously rising heating temperatures and prolonged duration, the moisture content variations in the subgrade become more pronounced. These significant variations in moisture will lead to dehydration, shrinkage, and cracking in the upper subgrade layers, thereby compromising the service performance and lifespan of the subgrade and pavement structures.

表1 试验黄土的基本物理性质指标Table 1 Basic physical properties of test loess |
| 天然湿密度ρ/ (g·cm-3) | 天然含水率 w(%) | 孔隙比e | 相对密度Gs |
|---|---|---|---|
| 1.62 | 13.21 | 0.996 | 2.70 |
| 最大干密度 ρdmax/(g·cm-3) | 最优含水率 wopc/% | 曲率系数 Cc | 不均匀系 数Cu |
| 1.74 | 15.8 | 1.508 | >5 |
| [1] |
于昕冉, 王乃昂. 近60 a甘肃省旅游气候舒适度变化分析[J]. 兰州大学学报(自然科学版), 2021, 57(2):143-150.
(
(
|
| [2] |
杨维涛, 孙建国, 康永泰, 等. 黄土高原地区极端气候指数时空变化[J]. 干旱区地理, 2020, 43(6): 1456-1466.
(
|
| [3] |
徐丽君, 卫琦, 徐俊增, 等. 中国北方干旱区降雨与相对湿度变化趋势的非一致性研究[J]. 水资源与水工程学报, 2021, 32(2): 38-44.
(
|
| [4] |
李建东, 王旭, 张延杰, 等. 球形蒸汽源增湿非饱和黄土水热运移规律试验研究[J]. 岩土工程学报, 2022, 44(4):687-695.
(
|
| [5] |
张升, 贺佐跃, 滕继东, 等. 非饱和土水汽迁移与相变: 两类“锅盖效应” 的试验研究[J]. 岩土工程学报, 2017, 39(5): 961-968.
(
|
| [6] |
|
| [7] |
|
| [8] |
|
| [9] |
陈佩佩, 乔栋, 吴楠. 非饱和成层土稳态渗流问题的解析计算[J]. 水文地质工程地质, 2024, 51(5):68-78.
(
|
| [10] |
荆鹏, 张雅琪, 宋心彤, 等. 强降雨及高温天气对风积沙路基水力特性的影响研究[J]. 铁道科学与工程学报, 2024, 21(2):5018-5029.
(
|
| [11] |
|
| [12] |
李颖颖. 非饱和土水汽迁移特性试验研究[D]. 西安: 长安大学, 2019.
(
|
| [13] |
林芸. 高温作用下非饱和黄土水分迁移研究[D]. 西安: 西安建筑科技大学, 2020.
(
|
| [14] |
赵再昆, 王铁行, 金鑫, 等. 高温作用下非饱和黄土水热迁移试验研究[J]. 岩土工程学报, 2024, 46(1):151-161.
(
|
| [15] |
张睿霞, 唐红, 姚海林, 等. 基于电阻率法的非饱和路基水汽迁移试验研究[J]. 长江科学院院报, 2023, 40(12):140-146.
(
|
| [16] |
|
| [17] |
|
| [18] |
崔宏志, 李建英, 刘宇飞, 等. 非饱和黏土中热湿耦合迁移规律研究[J/OL]. 工程力学,doi:10.6052/j.issn.1000-4750.2023.11.0864.
(
|
| [19] |
JTG 3430—2020, 公路土工试验规程[S]. 北京: 人民交通出版社, 2020.
(JTG 3430—2020, Test Methods of Soils for Highway Engineering[S]. Beijing: China Communications Press, 2020. (in Chinese))
|
| [20] |
|
/
| 〈 |
|
〉 |